Top > Releases ・ Announcements > Fukushima Daiichi NPS Prompt Report > 2013 > Steam-like Gas Found Near the Central Part of the Fifth Floor (Equipment Storage Pool Side) of Unit 3 Reactor Building at Fukushima Daiichi Nuclear Power Station (Follow-up Information 5)
This is a follow-up report on the statuses of steam-like gas found wafting through the air near the central part of the fifth floor (equipment storage pool side) of Unit 3 yesterday (July 18).
Please refer to the following dust analysis result, sampled at the north side of a space above the reactor at Unit 3 Reactor Building (sampled in a horizontal direction first time, sampled in a vertical direction and a horizontal direction second time) and at the northeast side of a space above the reactor (sampled in a vertical direction and a horizontal direction).
All results today were between the variation ranges of the past half year.
<1st sampling: Dust analysis result at the north side of a space above the reactor at Unit 3 Reactor Building (horizontal direction)>
Iodine 131: below the detection limit
Cesium 134: 1.1×10-4Bq/cm3
Cesium 137: 2.4×10-4Bq/cm3
<1st sampling: Dust analysis result at the north side of a space above the reactor at Unit 3 Reactor Building (vertical direction)> (Previously announced)
Iodine 131: below the detection limit
Cesium 134: 4.0×10-5Bq/cm3
Cesium 137: 7.1×10-5Bq/cm3
<2nd sampling: Dust analysis result at the north side of a space above the reactor at Unit 3 Reactor Building (vertical direction)>
Iodine 131: below the detection limit
Cesium 134: 1.2×10-5Bq/cm3
Cesium 137: 1.7×10-5Bq/cm3
<2nd sampling: Dust analysis result at the north side of a space above the reactor at Unit 3 Reactor Building (horizontal direction)>
Iodine 131: below the detection limit
Cesium 134: 1.5×10-5Bq/cm3
Cesium 137: 4.9×10-5Bq/cm3
<Dust analysis result at the northeast side of a space above the reactor at Unit 3 Reactor Building (vertical direction)>
Iodine 131: below the detection limit
Cesium 134: 5.3×10-5Bq/cm3
Cesium 137: 9.9×10-5Bq/cm3
<Dust analysis result at the northeast side of a space above the reactor at Unit 3 Reactor Building (horizontal direction)>
Iodine 131: below the detection limit
Cesium 134: 1.3×10-4Bq/cm3
Cesium 137: 2.7×10-4Bq/cm3
<Recent dust analysis result at the northeast side of a space above the reactor at Unit 3 Reactor Building (sampled on July 4)> (Previously announced)
(Vertical direction)
Iodine 131: below the detection limit
Cesium 134: below the detection limit
Cesium 137: 3.6×10-5Bq/cm3
(Horizontal direction)
Iodine 131: below the detection limit
Cesium 134: below the detection limit
Cesium 137: 2.5×10-5Bq/cm3
Please visit our web page for the sampling results.
http://www.tepco.co.jp/en/nu/fukushima-np/handouts/index-e.html