*new items are underlined
All 6 units of Fukushima Daiichi Nuclear Power Station have been shut down.
Unit 1(Shut down)
-Reactor has been shut down. However, the explosive sound and white smoke
were confirmed after the big quake occurred at 3:36 pm Mar 12th. It was
assumed to be hydrogen explosion.
-At approximately 2:30 am on March 23rd, seawater was started to be
injected to the nuclear reactor through the feed water system.
-At approximately 10:50 am on March 24th, white fog-like steam arising
from the roof part of the reactor building was observed.
-At approximately 11:30 am on March 24th, lights in the main control room
was restored.
-We had been injecting sea water into the reactor, but from 3:37 pm on
March 25th, we started injecting fresh water into it.
Unit 2(Shut down)
-At approximately 6:00 am on March 15th, an abnormal noise began emanating
from nearby Pressure Suppression Chamber and the pressure within this
chamber decreased.
-At 6:20 pm on March 21st, white smoke was confirmed arising from the top
of the reactor building. As of 7:11 am on March 22nd, smoke decreased to
the level to nearly non-existent.
-We have been injecting sea water into the reactor.
Unit 3(Shut down)
-Reactor has been shut down. However, the explosive sound and white smoke
were confirmed at 11:01am Mar 14th. It was assumed to be hydrogen
explosion.
-At 8:30am on March 16th, fog like steam was confirmed arising from the
reactor building.
-At approximately 6:15 am on March 17th the pressure of the Suppression
Chamber has temporarily increased. We were preparing to implement a
measurement to reduce the pressure of the reactor containment vessel
(partial discharge of air containing radioactive material to outside) in
order to fully secure safety. However, at present, it is not a situation
to take a measure immediately to discharge air containing radioactive
material to outside now. We will continue to monitor the status of the
pressure of the reactor containment vessel.
-At approximately 4:00 pm, March 21st, light gray smoke was confirmed
arising from the floor roof of the Unit 3 building. On March 22nd, the
color of smoke changed to somewhat white and it is slowly dissipating.
-At approximately 10:45 pm on March 22nd, the light in the main control
room was turned on.
-At around 4:20 pm on March 23rd, our staff confirmed light black smoke
belching from the Unit 3 building. At approximately 11:30 pm on March 23rd
and 4:50 am on March 24th, our employee found no signs of smoke.
-We had been injecting sea water into the reactor pressure vessel, but from
6:02 pm on March 25th, we started injecting fresh water into it.
Unit 4 (outage due to regular inspection)
-Reactor has been shut down. However, at approximately 6 am on March 15th.
We have confirmed the explosive sound and the sustained damage around the
5th floor rooftop area of the Nuclear Reactor Building.
-On March 15th and 16th, we respectively confirmed the outbreak of fire at
the 4th floor of the northwestern part of the Nuclear Reactor Building.
We immediately reported this matter to the fire department and the related
authorities. TEPCO employees confirmed that each fire had already died
down by itself.
-At this moment, we do not consider any reactor coolant leakage inside the
reactor happened.
Unit 5 (outage due to regular inspection)
-Reactor has been shut down and the sufficient level of reactor coolant to
ensure safety is maintained.
-At 5 am, March 19th, we started the Residual Heat Removal System Pump (C)
in order to cool the spent fuel pool.
-At this moment, we do not consider any reactor coolant leakage inside the
reactor containment vessel happened.
-At 2:30 pm, March 20th, the reactor achieved reactor cold shutdown. At
around 5:24 pm on March 23rd, when we switched the temporary Residual
Heat Removal System Seawater Pump, it has stopped automatically. At
around 4:14 pm, March 24th, we started replaced pump and at around 4:35
pm, cooling of reactor has restarted.
Unit 6 (outage due to regular inspection)
-Reactor has been shut down and the sufficient level of reactor coolant to
ensure safety is maintained.
-We are working on receiving external power supply to Units 5 and 6. We
completed the repair work on the emergency diesel generator (A).
-At 10:14 pm, March 19th, we started the Residual Heat Removal System Pump
(B) of Unit 6 in order to cool the spent fuel pool.
-At this moment, we do not consider any reactor coolant leakage inside the
reactor containment vessel happened.
-At 7:27 pm, March 20th, the reactor achieved reactor cold shutdown.
-In relation to the two seawater side pumps of the Residual Heat Removal
System, we changed the power source from temporary to permanent at 3:38
PM and 3:42PM, Mar 25 respectively. They are operating normally.
Today's work for cooling the spent fuel pools
-At :05 am, March 25th, we started injecting seawater into the spent fuel
pool of Unit 4, using Fuel Pool Cooling and Filtering(clean up) system
(FPC) and finished at 10:20 am. At 10:30 am, March 25th, we started
injecting seawater into the spent fuel pool of Unit 2, using Fuel Pool
Cooling and Filtering (clean up) system (FPC) and finished it at 0:19 pm
of the same day.
-Spraying at the spent fuel pool of Unit 3 by Kawasaki City Fire
Department was carried out from 1:28 pm to 4:00 pm on March 25th.
-From 7:05 PM to 10:07 PM, Mar 25, water discharge by concrete pumping
vehicle to the spent fuel pool of Unit 4 was conducted.
-We are considering further spraying at other units and others subject to
the conditions of spent fuel pools.
Casualty
-2 workers of cooperative firm were injured at the occurrence of the
earthquake, and were transported to the hospital on March 11th.
-Presence of 2 TEPCO employees at the site is not confirmed on March 11th.
-1 TEPCO employee who was not able to stand by his own holding left chest
with his hand, was transported to the hospital by an ambulance on March
12th.
-4 workers were injured and transported to the hospital after explosive
sound and white smoke were confirmed around the Unit 1on March 12th.
-1 subcontract worker at the key earthquake-proof building was unconscious
and transported to the hospital by an ambulance on March 12th.
-The radiation exposure of 1 TEPCO employee, who was working inside the
reactor building, exceeded 100mSv and he was transported to the hospital
on March 12th.
-2 TEPCO employees felt bad during their operation in the central control
rooms of Unit 1 and 2 while wearing full masks, and were transferred to
Fukushima Daini Nuclear Power Station for consultation with a medical
advisor on March 13th.
-11 workers were injured and transported to Fukushima Daini Nuclear Power
Station etc. after explosive sound and white smoke were confirmed around
the Unit 3. One of the workers was transported to the FUKUSHIMA Medical
University Hospital on March 14th.
-At approximately 10 pm on March 22nd, 1 worker who had been working on
setting up a temporary power panel in the common pool was injured and
transported to Fukushima Daini Nuclear Power Station where the industrial
doctor is.
-At approximately 1:30 am on March 23rd, 1 worker who had been working on
transporting a temporary power panel in the common pool was injured and
transported to Fukushima Daini Nuclear Power Station where the industrial
doctor is.
-On March 24th, it was confirmed that 3 workers from cooperative companies
who were in charge of cable laying work in the 1st floor and the
underground floor of turbine building were exposed to the radiation dose
of more than 170 mSv. 2 of them were confirmed that their leg skin were
contaminated. Although they were decontaminated, since it there were
possibility of beta ray burn injury, they were transferred to Fukushima
Medical University Hospital. The third worker was also transferred to
Fukushima Medical University Hospital today (March 25). The 3 workers are
now been transferred to National Institute of Radiological Sciences in
Chiba Prefecture.
Regarding this event, TEPCO has reported to related government ministries
and agencies on measures to be taken to assure appropriate radiation dose
control and radiation exposure related operations.
Before today's restoration work, we will make notification to
the concerned parties and continue to take all possible measures to
future management.
Others
-We measured radioactive materials (iodine etc.) inside of the nuclear
power station area (outdoor) by monitoring car and confirmed that
radioactive materials level is getting higher than ordinary level. As
listed below, we have determined that specific incidents stipulated in
article 15, clause 1 of Act on Special Measures Concerning Nuclear
Emergency Preparedness (Abnormal increase in radiation dose measured at
site boundary) have occurred.
·Determined at 4:17 pm Mar 12th (Around Monitoring Post 4 )
·Determined at 8:56 am Mar 13th (Around Monitoring Post 4 )
·Determined at 2:15 pm Mar 13th (Around Monitoring Post 4 )
·Determined at 3:50 am Mar 14th (Around Monitoring Post 6 )
·Determined at 4:15 am Mar 14th (Around Monitoring Post 2 )
·Determined at 9:27 am Mar 14th (Around Monitoring Post 3 )
·Determined at 9:37 pm Mar 14th (Around main entrance )
·Determined at 6:51 am Mar 15th (Around main entrance )
·Determined at 8:11 am Mar 15th (Around main entrance )
·Determined at 4:17 pm Mar 15th (Around main entrance )
·Determined at 11:05 pm Mar 15th (Around main entrance )
·Determined at 8:58 am Mar 19th (Around MP5)
From now on, if the measured figure fluctuates and goes above and below
500 micro Sv/h, we deem that as the continuous same event and will not
regard that as a new specific incidents stipulated in article 15, clause 1
of the Act on Special Measures Concerning Nuclear Emergency Preparedness
(Abnormal increase in radiation dose measured at site boundary) has
occurred. In the interim, if we measure a manifestly abnormal figure and
it is evident that the event is not the continuous same event, we will
determine and notify.
-The national government has instructed evacuation for those local
residents within 20km radius of the periphery and evacuation to inside
for those residents from 20km to 30km radius of the periphery, because
it's possible that radioactive materials are discharged.
-At approximately 10am on March 15th, we observed 400mSv/h at the inland
side of the Unit 3 reactor building and 100mSv/h at the inland side of
the Unit 4 reactor building.
-At around 10:37 am March 21st, water spraying to common spent fuel pool
and finished at 3:30 pm (conducted by TEPCO).
-At around 3:37 pm, March 24th, electricity supply to common spent fuel
pool has started from external power source. At around 6:05 pm, fuel pool
cooling pump was started to cool the pool.
-We found no signs of abnormal situation for the casks by visual
observation during the patrol activity. A detailed inspection is under
preparation.
-At Units 5 and 6, in order to prevent hydrogen gas from accumulating
within the buildings, we have made three holes on the roof of the reactor
building for each unit.
-In total 12 fire engines are lent for the water spraying to the spent
fuel pools and water injection to the nuclear reactors by various
regional fire departments* as well as Tokyo Fire Department. Also,
instruction regarding the setting and operation of large scale
decontamination system was provided by Niigata City Fire Headquarter and
Hamamatsu City Fire Headquarter.
*: Koriyama Fire Department, Iwaki Fire Brigade Headquarters, Fire
Headquarters of Sukagawa District Wide Area Fire-fighting Association,
Yonezawa City Fire Headquarters, Utsunomiya City Fire Headquarters,
Fire Headquarters of Aizu-Wakamatsu wide area municipal association,
Saitama City Fire Bureau, and Niigata City Fire Bureau.
-By March 22nd, Units 1 through 6 were started to be energized from the
external power source.
-We will continue to take all measures to ensure the safety and to
continue monitoring the surrounding environment around the Power Station.